| CAREvent® EMT |
|
 |
|
| |
The “NEW” CAREvent® EMT
- Automatic Resuscitation with A.T.T.I.T.U.D.E.®!
Trained individuals now have a safe, effective and inexpensive
means of providing positive pressure ventilation during respiratory
and/or cardiac arrest.
Providing “TRUE AUTOMATIC VENTILATION” at an
affordable price, the lightweight, portable, simple to use
and extremely durable CAREvent EMT® Handheld Resuscitator
is designed for the demands of the emergency resuscitation
and transport environment. In addition, this pneumatically
powered, time/volume cycled ventilator has the added feature
of a Manually Actuated, Automatic Ventilation Override Button
(Manual Button) for use during CPR.
Depressing the Manual
Button overrides the automatic cycling and allows the operator
to provide the breaths manually in
time with the chest compressions. Depression of the button
inhibits the automatic cycling for 10 seconds. This allows
the rescuer to provide the 15 chest compressions in accordance
with the Guidelines 2000 for Resuscitation (G2K®) without
the ventilator attempting to provide the next breath during
the compression cycle. If the Manual Button is not depressed
again the automatic cycling will re-start without any intervention
by the operator. The second breath can then be provided manually.
The ventilator cycling will then stop for 10 seconds, allowing
the next set of compressions to be provided.
The Single Slider
Control provides the simultaneous adjustment of ventilation
frequency and tidal volume. The CAREvent EMT® has
six, preset, tidal volume / frequency settings for a range
of patients from 15 kg., body weight to large adults. An
OFF position is provided so that the device can be left attached
to the gas supply with the supply turned on ready for immediate
use.
The patient is protected from barotrauma due to over
inflation by the Pressure Relief System (with audible alarm).
This
warns the operator of airway obstruction or restriction.
The excess delivered volume is discharged to atmosphere when
the alarm activates.
|
|
|
A.utomatic |
|
T.ime cycled |
|
T.idal volume/frequency controlled |
|
I.:E ratio constant (1:2) |
|
T.rigger (MANUAL OVERRIDE) for CPR |
|
U.naffected by lung/airway changes |
|
D.elay on Manual Override - G2K* compliant. |
|
E.xtremely low drive gas consumption |
| |
Tidal Volume:
|
0.15 - 0.6 litres |
| |
Breaths Per Minute: |
20 - 10 |
| |
I:E Ratio: |
1:2 |
| |
Manual Flow Rate Range: |
As per Vt/BPM Control Setting |
| |
Input Pressure: |
50 PSI (+/- 10 PSI) |
| |
Audible Pressure Relief Valve: |
60 cm H20 |
| |
Operating Temperature: |
-18°C to +50°C
(0°F to 122°F) |
| |
Storage Temperature: |
-40°C to +60°C
(-40°F to 140°F) |
| |
Relative Humidity for Storage and Operating Use:
|
15 to 95% |
| |
Input Connection: |
Fixed |
| |
Hose connection to regulator: |
9/16 DISS |
| |
Patient Valve Dead Space: |
8 ml. |
| |
Dimensions (inches): |
5.5 x 2.5 x 2.9 (approx.) |
| |
Dimensions (millimeters): |
140 x 63 x 73 (approx.) |
| |
Weight: |
0.95lbs / 0.43kg |
| |
(All specifications are
subject to a tolerance of +/- 10%
except the I:E Ratio which is subject to a tolerance of +/- 20%) |
 |
Part
Number and Product Description |
 |
|
 |
| |
01CV0500 |
CAREvent EMT® Handheld Automatic Resuscitator
and Supply Hose, c/w 5 Single-Use Patient Valves with
Universal Resuscitation Facemasks. |
|
| |
 |
| CAREvent® ALS |
|
 |
|
| |
The
CAREvent® ALS Handheld Resuscitator is lightweight,
portable, extremely durable and simple to use automatic
time/volume cycled ventilatory resuscitator with “Demand
Breathing Capability” for the spontaneously breathing
patient. The added feature of a Manually Actuated, Automatic
Ventilation Override Button (Manual Button) allows the
operator to control the ventilations manually if required.
The single slider control for the simultaneous adjustment of
ventilation frequency and tidal volume has 6 preset settings
for a range of patients from infants to large adults and an
OFF position so that the resuscitator can be left attached
to the gas supply with the supply turned on, ready for immediate
use.
During CPR actuation of the manual button causes the automatic
cycling to cease to allow the provision of chest compressions.
Cycling will re-start following manual actuation after a delay
of 4 to 7 seconds depending on the selected setting of the
slider control.
The Demand Breathing feature allows the patient to spontaneously
breathe through the resuscitator on 100% oxygen, at their own
desired rate and volume. In addition, the patient’s inspiratory
efforts cause the automatic cycling to cease. Should the patient
cease breathing spontaneously, the ventilator will automatically
restart cycling in the automatic setting selected.
Note: In the child settings the inspired flow rate of the patient
may be insufficient to cause the Automatic Circuit Shutoff
to function.
The pneumatic logic circuit can be run off either compressed
air or medical oxygen.
CAREvent® ALS “G2K” Resuscitator
Designed to comply with the latest CPR Guidelines 2000 recommendations
of a 15:2 compression:ventilation ratio in the un-intubated
patient, this model has a 10 second delay to automatic cycling
re-start “in any setting”, following manual ventilation
actuation, to allow for 15 chest compressions to be provided.
|
|
|
Totally pneumatic operation |
|
Lightweight |
|
Durable |
|
Automatic & Manual Cycling |
|
Demand Breathing Capability with auto circuit shut off |
|
Preset Pressure Relief |
|
G2K Compliant Version Available |
|
2 Year Warranty Against Manufacturers Defects |
| |
TIDAL VOLUME:
|
0.2-1.1 litres |
| |
BREATHS PER MINUTE: |
20-12 |
| |
I:E RATIO |
1:2 |
| |
AUTOMATIC FLOW RATE: |
12-39.6 LPM |
| |
MANUAL FLOW RATE: |
As per selected setting |
| |
DEMAND FLOWRATE: |
Minimum 120 LPM |
| |
MINIMUM INPUT PRESSURE: |
45 PSI |
| |
MAXIMUM INPUT PRESSURE: |
70 PSI |
| |
MAX . AIRWAY PRESSURE: |
60 cm H2O |
| |
OPERATING TEMPERATURE: |
-18°C to +50°C
0°F to +122°F |
| |
STORAGE TEMPERATURE: |
-40°C to +60°C
-40°F to + 140°F |
| |
PATIENT CONNECTION: |
9/16" DISS |
| |
CYLINDER DURATION: |
(a) 20 BPM / 0.2 I VT 100 minutes (approx.)
(b) 12 BPM / 1.1 I V 30 minutes (approx.)
(Based on Aluminum "D" size cylinder containing 415 litres of oxygen) |
| |
(All specifications are
subject to a tolerance of +/- 10%
except the I:E Ratio
which is subject to a tolerance of +/- 20%) |
 |
Part
Number and Product Description |
 |
|
 |
| |
01CV3000 |
CAREvent® ALS Handheld Automatic Time/volume
Cycled Resuscitator c/w 6 foot supply hose and Universal
Face Mask |
| |
01CV3100 |
CAREvent® ALS Handheld Resuscitator kit with Adjustable
0 – 25LPM Regulator with 2 DISS Self-Sealing outlets
in a moulded Carrying Case c/w 6 foot supply hose and
Universal Face Mask |
| |
01CV3112 |
CAREvent® ALS Handheld Resuscitator kit with Adjustable
0 – 25LPM Regulator with 2 DISS Self-Sealing outlets
and STATVAC® II Aspirator in a moulded Carrying Case
c/w 6 foot supply hose Yankauer Suction Tip with Tubing
and Universal Face Mask |
|
| |
 |
| CAREvent® ALS+ |
|
 |
|
| |
The
CAREvent® ALS+ is lightweight, portable, extremely
durable and simple to use, control module style, automatic
time/volume cycled ventilatory resuscitator with “Demand
Breathing Capability” for the spontaneously breathing
patient. The added feature of a Manually Actuated, Automatic
Ventilation Override Button (Manual Button) allows the
operator to control the ventilations manually if required.
The single rotary control provides simultaneous adjustment
of ventilation frequency and tidal volume has 12 preset settings
for a range of patients from infants to large adults. A Manual/Auto
switch allows the resuscitator to be left attached to the gas
supply with the supply turned on, ready for immediate use.
During CPR actuation of the manual button causes the automatic
cycling to cease to allow the provision of chest compressions.
Cycling will re-start following manual actuation after a delay
of 4 to 7 seconds depending on the selected setting of the
slider control.
The Demand Breathing feature allows the patient to spontaneously
breathe through the resuscitator on 100% oxygen, at their own
desired rate and volume. In addition, the patient’s inspiratory
efforts cause the automatic cycling to cease. Should the patient
cease breathing spontaneously, the ventilator will automatically
restart cycling in the automatic setting selected.
Note: In the child settings the inspired
flow rate of the patient may be insufficient to cause the Automatic
Circuit Shut off
to function.
The pneumatic logic circuit can be run off either compressed
air or medical oxygen.
Designed to comply with the latest CPR Guidelines 2000 recommendations
of a 15:2 compression:ventilation ratio in the un-intubated
patient, the CAREvent® ALS+ “G2K” model has
a 10 second delay to automatic cycling re-start “in any
setting”, following manual ventilation actuation, to
allow for 15 chest compressions to be provided.
|
|
|
Totally pneumatic operation |
|
Lightweight |
|
Durable |
|
Control Module Style |
|
Manual/Auto Selector Switch |
|
Automatic & Manual Cycling |
|
Demand Breathing Capability with auto circuit shut off |
|
Preset Pressure Relief |
|
G2K Compliant Version Available |
|
2 Year Warranty Against Manufacturers Defects |
| |
TIDAL VOLUME:
|
0.2-1.35 litres |
| |
BREATHS PER MINUTE: |
20-10 |
| |
I:E RATIO: |
1:2 |
| |
AUTOMATIC FLOW RATE: |
12- 40 LPM |
| |
MANUAL FLOW RATE: |
As per selected setting |
| |
DEMAND FLOWRATE: |
Minimum 120 LPM |
| |
MINIMUM INPUT PRESSURE: |
45 PSI |
| |
MAXIMUM INPUT PRESSURE: |
70 PSI |
| |
MAX. AIRWAY PRESSURE: |
60 cm H2O |
| |
OPERATING TEMPERATURE: |
-18°C to +50°C
0°F to +122°F |
| |
STORAGE TEMPERATURE: |
-40°C to +60°C
-40°F to + 140°F |
| |
PATIENT CONNECTION: |
9/16" DISS |
| |
CYLINDER DURATION: |
(a) 20 BPM / 0.2 I VT 100 minutes (approx.)
(b) 12 BPM / 1.1 I V 30 minutes (approx.)
(Based on Aluminum "D" size cylinder containing 415 litres of oxygen) |
| |
(All specifications are
subject to a tolerance of +/- 10%
except the I:E Ratio
which is subject to a tolerance of +/- 20%) |
 |
Part
Number and Product Description |
 |
|
 |
| |
01CV4000 |
CAREvent® ALS+ Control Module Automatic
Time/volume Cycled Resuscitator c/w 6 foot supply hose,
Deluxe Disposable Transport Ventilator Circuit, Test
Lung and Universal Face Mask |
|
| |
 |
| CAREvent®
ATV |
|
 |
|
| |

The
CAREvent® ATV is an Intermittent Positive Pressure
ventilator with independent frequency of ventilation and
Minute Volume settings to provide a comprehensive selection
of delivered tidal volumes and ventilation rates. The design
of the micro-pneumatic circuitry in the Automatic Transport
Ventilator maintains a consistent I:E Ratio set at 1:2
throughout the entire setting range. Designed for use by
suitably trained personnel in the prehospital, inter-hospital
and air ambulance settings. The various modes of operation
of the ventilator support the resuscitation and transportation
of a wide range of patients (from infants to adults) who
require ventilatory support.
The added feature of a Manually Actuated, Automatic Ventilation
Override Button (Manual Button) to allow the operator to control
the ventilations manually if required. In the AUTOmatic mode,
the automatic cycling will re-start following manual actuation
after a delay of 4 to 7 seconds depending on the selected setting.
In the MANual mode the automatic cycling is completely inhibited
allowing the operator to fully control the ventilations.
Peak airway pressure is operator adjustable to allow for differing
patient conditions.
The "Demand Breathing" feature allows spontaneously
breathing patients to breathe on oxygen through the ventilator.
The "Automatic Circuit Shut Off" control will cause
the automatic cycling to cease when the patient being ventilated
takes a spontaneous breath.
Note: In the child settings the inspired
flow rate of the patient may be insufficient to cause the Automatic
Circuit Shut off
to function.
The CAREvent® ATV consists of a ruggedly constructed, portable
control module, input hose and optional single use or reusable
patient circuit. The ergonomically designed control groupings
facilitate the selection and setting of the breathing parameters.
The colour groupings provided on the controls add to this ease
of use and concept.
The unique pneumatic alarm for low input pressure improves
the level of safety for the patient by warning the operator
of any problems in the gas supply.
The air mix capability of the ventilator improves the operating
time on bottled oxygen for long duration transports. The extremely
low drive gas consumption ensures full utilization of the cylinder
contents. As an added precaution a replaceable filter is incorporated
into the rear of the ventilator to prevent contaminated air
entering into the unit when using the air mix mode.
Designed to comply with the latest CPR Guidelines 2000 recommendations
of a 15:2 compression:ventilation ratio in the un-intubated
patient, the CAREvent® ATV “G2K” model has
a 10 second delay to automatic cycling re-start “in any
setting”, following manual ventilation actuation, to
allow for 15 chest compressions to be provided.
|
|
|
Totally pneumatic operation |
|
Durable construction |
|
Independent Minute volume and Frequency controls |
|
Manual/Auto Selector Switch |
|
Automatic & Manual Cycling |
|
Low input Pressure Alarm |
|
Demand Breathing Capability with auto circuit shut off |
|
Adjustable Pressure Relief |
|
G2K Compliant Version Available |
|
2 Year Warranty Against Manufacturers Defects |
| |
MINUTE VOLUME:
|
2 - 14 litres |
| |
BREATHS PER MINUTE: |
8 - 40 |
| |
I:E RATIO: |
1:2 |
| |
AUTOMATIC FLOW RATE: |
12- 40 LPM |
| |
MANUAL FLOW RATE: |
As per selected setting |
| |
DEMAND FLOWRATE: |
Minimum 120 LPM |
| |
DEMAND TRIGGERING PRESSURE |
-5 cm H20 @ 100 LPM |
| |
MINIMUM INPUT PRESSURE: |
45 PSI |
| |
MAXIMUM INPUT PRESSURE:
|
70 PSI |
| |
MAX . AIRWAY PRESSURE: |
60 cm H2O |
| |
OXYGEN CONCENTRATION: |
60 or 100% |
| |
ADJUSTABLE AIRWAY PRESSURE RANGE: |
20 – 60 cm H2O |
| |
OPERATING TEMPERATURE: |
-18°C to +50°C
0°F to +122°F |
| |
STORAGE TEMPERATURE: |
-40°C to +60°C
-40°F to + 140°F |
| |
PATIENT CONNECTION: |
9/16” DISS |
| |
PATIENT VALVE DEADSPACE: |
8 ml |
| |
GAS SUPPLY STATUS INDICATOR:
|
VISUAL |
| |
LOW INPUT PRESSURE ALARM: |
PULSED VISUAL and AUDIBLE |
| |
CYLINDER DURATION: |
AT 5L MV - 75minutes (approx.)
(Based on Aluminum "D" size cylinder containing 415 litres of oxygen) |
| |
(All specifications are
subject to a tolerance of +/- 10%
except the I:E Ratio
which is subject to a tolerance of +/- 20%) |
 |
Part
Number and Product Description |
 |
|
 |
| |
01CV5000 |
CAREvent® ATV Control Automatic Transport
Ventilator c/w 6 foot supply hose, Deluxe Disposable
Transport Ventilator Circuit, Test Lung and Universal
Face Mask |
|
| |
 |
| CAREvent®
ATV+ |
|
 |
|
| |
|

The
CAREvent® ATV+ is an Intermittent Positive Pressure ventilator
with independent frequency of ventilation and Minute Volume
settings to provide a comprehensive selection of delivered
tidal volumes and ventilation rates. The design of the micro-pneumatic
circuitry in the Automatic Transport Ventilator maintains
a consistent I:E Ratio set at 1:2 throughout the entire setting
range. Designed for use by suitably trained personnel in
the prehospital, inter-hospital and air ambulance settings.
The various modes of operation of the ventilator support
the resuscitation and transportation of a wide range of patients
(from infants to adults) who require ventilatory support.
The added feature of a Manually Actuated, Automatic Ventilation
Override Button (Manual Button) to allow the operator to control
the ventilations manually if required. In the AUTOmatic mode,
the automatic cycling will re-start following manual actuation
after a delay of 4 to 7 seconds depending on the selected setting.
In the MANual mode the automatic cycling is completely inhibited
allowing the operator to fully control the ventilations.
Peak airway pressure is operator adjustable to allow for differing
patient conditions.
The "Demand Breathing" feature allows spontaneously
breathing patients to breathe on oxygen through the ventilator.
The "Automatic Circuit Shut Off" control will cause
the automatic cycling to cease when the patient being ventilated
takes a spontaneous breath.
Note: In the child settings the inspired
flow rate of the patient may be insufficient to cause the Automatic
Circuit Shut off
to function.
The CAREvent® ATV+ Automatic Transport Ventilator consists
of a ruggedly constructed, portable control module, input hose
and optional single use or reusable patient circuit. The ergonomically
designed control groupings facilitate the selection and setting
of the breathing parameters. The colour groupings provided
on the controls add to this ease of use and concept.
The unique pneumatic alarm for low input pressure improves
the level of safety for the patient by warning the operator
of any problems in the gas supply. An alarm for patient circuit
disconnection or insufficient tidal volume delivery is also
incorporated in all three models. This pneumatically powered
alarm provides both a visual and audible indication of patient
circuit disconnection. The silence button will override the
alarm for 15 seconds.
Should the operator not correct the problem
in that time the alarm will recommence.
The air mix capability of the ventilator improves the operating
time on bottled oxygen for long duration transports. The extremely
low drive gas consumption ensures full utilization of the cylinder
contents. As an added precaution a replaceable filter is incorporated
into the rear of the ventilator to prevent contaminated air
entering into the unit when using the air mix mode.
Designed to comply with the latest CPR Guidelines 2000 recommendations
of a 15:2 compression:ventilation ratio in the un-intubated
patient, the CAREvent® ATV “G2K” model has
a 10 second delay to automatic cycling re-start “in any
setting”, following manual ventilation actuation, to
allow for 15 chest compressions to be provided.
|
|
|
Totally pneumatic operation |
|
Durable construction |
|
Independent Minute volume and Frequency controls |
|
Manual/Auto Selector Switch |
|
Automatic & Manual Cycling |
|
Circuit Disconnect Alarm |
|
Low input Pressure Alarm |
|
Demand Breathing Capability with auto circuit shut off |
|
Adjustable Pressure Relief |
|
G2K Compliant Version Available |
|
2 Year Warranty Against Manufacturers Defects |
| |
MINUTE VOLUME:
|
2 - 14 litres |
| |
BREATHS PER MINUTE: |
8 - 40 |
| |
I:E RATIO: |
1:2 |
| |
AUTOMATIC FLOW RATE: |
12- 40 LPM |
| |
MANUAL FLOW RATE: |
As per selected setting |
| |
DEMAND FLOWRATE: |
Minimum 120 LPM |
| |
DEMAND TRIGGERING PRESSURE: |
-5 cm H20 @ 100 LPM |
| |
MINIMUM INPUT PRESSURE: |
45 PSI |
| |
MAXIMUM INPUT PRESSURE:
|
70 PSI |
| |
MAX . AIRWAY PRESSURE: |
60 cm H2O |
| |
OXYGEN CONCENTRATION: |
60 or 100% |
| |
ADJUSTABLE AIRWAY PRESSURE RANGE: |
20 – 60 cm H2O |
| |
OPERATING TEMPERATURE: |
-18°C to +50°C
0°F to +122°F |
| |
STORAGE TEMPERATURE: |
-40°C to +60°C
-40°F to + 140°F |
| |
PATIENT CONNECTION: |
9/16” DISS |
| |
PATIENT VALVE DEADSPACE: |
8 ml |
| |
GAS SUPPLY STATUS INDICATOR:
|
VISUAL |
| |
CIRCUIT DISCONNECT ALARM:
|
PULSED AUDIBLE, AND VISUAL. ALARM SILENCE CONTROL – 15 SECONDS |
| |
LOW INPUT PRESSURE ALARM: |
PULSED VISUAL and AUDIBLE |
| |
CYLINDER DURATION: |
AT 5L MV - 75minutes (approx.)
(Based on Aluminum "D" size cylinder containing 415 litres of oxygen) |
| |
(All specifications are
subject to a tolerance of +/- 10%
except the I:E Ratio
which is subject to a tolerance of +/- 20%) |
 |
Part
Number and Product Description |
 |
|
 |
| |
01CV6000 |
CAREvent® ATV+ Control Automatic Transport
Ventilator c/w 6 foot supply hose, Deluxe Disposable
Transport Ventilator Circuit, Test Lung and Universal
Face Mask |
|
| |
 |
| CAREvent®
MRI |
|
 |
|
| |
|

The
CAREvent® MRI is an Intermittent Positive Pressure ventilator
with independent frequency of ventilation and Minute Volume
settings to provide a comprehensive selection of delivered
tidal volumes and ventilation rates. The design of the micro-pneumatic
circuitry in the Automatic Transport Ventilator maintains
a consistent I:E Ratio set at 1:2 throughout the entire setting
range. Designed for use by suitably trained personnel in
the prehospital, inter-hospital and air ambulance settings.
The various modes of operation of the ventilator support
the resuscitation and transportation of a wide range of patients
(from infants to adults) who require ventilatory support.
The added feature of a Manually Actuated, Automatic Ventilation
Override Button (Manual Button) to allow the operator to control
the ventilations manually if required. In the AUTOmatic mode,
the automatic cycling will re-start following manual actuation
after a delay of 4 to 7 seconds depending on the selected setting.
In the MANual mode the automatic cycling is completely inhibited
allowing the operator to fully control the ventilations.
Peak airway pressure is operator adjustable to allow for differing
patient conditions.
The "Demand Breathing" feature allows spontaneously
breathing patients to breathe on oxygen through the ventilator.
The "Automatic Circuit Shut Off" control will cause
the automatic cycling to cease when the patient being ventilated
takes a spontaneous breath.
Note: In the child settings the inspired
flow rate of the patient may be insufficient to cause the Automatic
Circuit Shut off
to function.
The CAREvent® MRI Automatic Transport Ventilator consists
of a ruggedly constructed, portable control module, input hose
and optional single use or reusable patient circuit. The ergonomically
designed control groupings facilitate the selection and setting
of the breathing parameters. The colour groupings provided
on the controls add to this ease of use and concept.
The unique pneumatic alarm for low input pressure improves
the level of safety for the patient by warning the operator
of any problems in the gas supply. An alarm for patient circuit
disconnection or insufficient tidal volume delivery is also
incorporated in all three models. This pneumatically powered
alarm provides both a visual and audible indication of patient
circuit disconnection. The silence button will override the
alarm for 15 seconds. Should the operator not correct the problem
in that time the alarm will recommence.
The air mix capability of the ventilator improves the operating
time on bottled oxygen for long duration transports. The extremely
low drive gas consumption ensures full utilization of the cylinder
contents. As an added precaution a replaceable filter is incorporated
into the rear of the ventilator to prevent contaminated air
entering into the unit when using the air mix mode.
Designed to comply with the latest CPR Guidelines 2000 recommendations
of a 15:2 compression:ventilation ratio in the un-intubated
patient, the CAREvent® ATV “G2K” model has
a 10 second delay to automatic cycling re-start “in any
setting”, following manual ventilation actuation, to
allow for 15 chest compressions to be provided.
|
|
|
MRI compatible |
|
Totally pneumatic operation |
|
Durable construction |
|
Independent Minute volume and Frequency controls |
|
Manual/Auto Selector Switch |
|
Automatic & Manual Cycling |
|
Circuit Disconnect Alarm |
|
Low input Pressure Alarm |
|
Demand Breathing Capability with auto circuit shut off |
|
Adjustable Pressure Relief |
|
G2K Compliant Version Available |
|
2 Year Warranty Against Manufacturers Defects |
| |
MINUTE VOLUME: |
2 - 14 litres |
| |
BREATHS PER MINUTE: |
8 - 40 |
| |
I:E RATIO: |
1:2 |
| |
AUTOMATIC FLOW RATE: |
12- 40 LPM |
| |
MANUAL FLOW RATE: |
As per selected setting |
| |
DEMAND FLOWRATE: |
Minimum 120 LPM |
| |
DEMAND TRIGGERING PRESSURE: |
-5 cm H20 @ 100 LPM |
| |
MINIMUM INPUT PRESSURE: |
45 PSI |
| |
MAXIMUM INPUT PRESSURE:
|
70 PSI |
| |
MAX . AIRWAY PRESSURE: |
60 cm H2O |
| |
OXYGEN CONCENTRATION: |
60 or 100% |
| |
ADJUSTABLE AIRWAY PRESSURE RANGE: |
20 – 60 cm H2O |
| |
OPERATING TEMPERATURE: |
-18°C to +50°C
0°F to +122°F |
| |
STORAGE TEMPERATURE: |
-40°C to +60°C
-40°F to + 140°F |
| |
PATIENT CONNECTION: |
9/16” DISS |
| |
PATIENT VALVE DEADSPACE: |
8 ml |
| |
GAS SUPPLY STATUS INDICATOR:
|
VISUAL |
| |
CIRCUIT DISCONNECT ALARM:
|
PULSED AUDIBLE, AND VISUAL.
ALARM SILENCE CONTROL – 15 SECONDS |
| |
LOW INPUT PRESSURE ALARM: |
PULSED VISUAL and AUDIBLE |
| |
CYLINDER DURATION: |
AT 5L MV - 75minutes (approx.)
(Based on Aluminum "D" size cylinder containing 415 litres of oxygen) |
| |
(All specifications are
subject to a tolerance of +/- 10%
except the I:E Ratio
which is subject to a tolerance of +/- 20%) |
 |
Part
Number and Product Description |
 |
|
 |
| |
01CV7000 |
CAREvent® MRI Control Automatic Transport
Ventilator c/w 6 foot supply hose, Deluxe Disposable
Transport Ventilator Circuit, Test Lung and Universal
Face Mask |
|
| |
 |
| CAREvent®
CA |
|
 |
|
| |
Specifically
designed for the “Chemical Agent Resuscitation Environment”,
the CAREvent® CA Handheld Resuscitator is lightweight,
portable, extremely durable and simple to use automatic time/volume
cycled ventilatory resuscitator with “Demand Breathing
Capability” for the spontaneously breathing patient.
The added feature of a Manually Actuated, Automatic Ventilation
Override Button (Manual Button) allows the operator to control
the ventilations manually if required.
The CAREvent® CA combines simplicity of operation with
technological sophistication to provide automatic ventilation,
at a rate and volume designed to reduce the risk of gastric
insufflation. It also provides Demand Breathing and "Automatic
Circuit Shut Off" of the automatic cycling unit should
the patient begin adequate spontaneous respiration.
Designed to comply with the latest CPR Guidelines 2000 recommendations of a 15:2
compression:ventilation ratio in the un-intubated patient, actuation of the manual
button causes the automatic cycling to cease. This model has a 10 second delay
to automatic cycling re-start “in any setting”, following manual
ventilation actuation, to allow for 15 chest compressions to be provided.
The Demand Breathing feature allows the patient to spontaneously breathe through
the resuscitator on 100% oxygen, at their own desired rate and volume. In addition,
the patient’s inspiratory efforts cause the automatic cycling to cease.
Should the patient cease breathing spontaneously, the ventilator will automatically
restart cycling in the automatic setting selected.
The added feature of this unit is the MASK PURGE (2 lpm) CONSTANT BLEED FLOW.
This reduces the risk of drawing toxic atmosphere into the mask if a leak in
the mask to face seal occurs.
Note: In the child settings the inspired flow rate of the patient may be insufficient
to cause the Automatic Circuit Shut off to function.
The pneumatic logic circuit can be run off either compressed air or medical oxygen.
|
|
|
Totally pneumatic operation |
|
Lightweight |
|
Durable |
|
Automatic & Manual Cycling |
|
Mask purge “Bleed Flow” |
|
Demand Breathing Capability with auto circuit shut off |
|
Preset Pressure Relief |
|
2 Year Warranty Against Manufacturers Defects |
| |
TIDAL VOLUME:
|
0.8 litres |
| |
BREATHS PER MINUTE: |
12 |
| |
I:E RATIO: |
1:2 |
| |
AUTOMATIC FLOW RATE: |
28.8 LPM |
| |
MANUAL FLOW RATE: |
28.8 LPM |
| |
DEMAND FLOWRATE:
|
Minimum 120 LPM |
| |
MSK PURGE BLEED FLOW: |
2 LPM |
| |
MINIMUM INPUT PRESSURE: |
45 PSI |
| |
MAXIMUM INPUT PRESSURE:
|
70 PSI |
| |
MAX . AIRWAY PRESSURE: |
60 cm H2O |
| |
OPERATING TEMPERATURE: |
-18°C to +50°C
0°F to +122°F |
| |
STORAGE TEMPERATURE: |
-40°C to +60°C
-40°F to + 140°F |
| |
PATIENT CONNECTION: |
9/16" DISS |
| |
CYLINDER DURATION: |
12 BPM / 0.8 VT 43 minutes (approx.)
(Based on Aluminum "D" size cylinder containing 415 litres of oxygen) |
| |
(All specifications are
subject to a tolerance of +/- 10%
except the I:E Ratio
which is subject to a tolerance of +/- 20%) |
 |
Part
Number and Product Description |
 |
|
 |
| |
01CV3000-CA |
CAREvent® CA Chemical Agent Resuscitation
Environment Handheld Automatic Time/volume Cycled Resuscitator
c/w 6 foot supply hose and Universal Face Mask |
|
| |
 |
| Resuscitator/Ventilator
Accessories |
|
 |
|
| |
The
CAREvent® and Genesis® II ventilator/resuscitator
accessories range have been designed for use with our Automatic
Transport Ventilators and resuscitators. These high quality/high
performance components are an essential adjunct to our resuscitation
and ventilation products.
Because of their high quality, our
Transport Ventilator Circuits can be utilized on ventilators
from other manufacturers
however we do not recommend the use of other manufacturer’s
products on our ventilators and resuscitators.
|
|
|
Manufactured from the finest materials |
|
Durable |
|
High performance |
|
High quality |
 |
Part
Number and Product Description |
 |
|
 |
| |
01CV8001-cs
|
CAREvent® BLS Single Use Patient
Valve c/w Universal Facemask – case/25 |
| |
01CV8005-cs |
CAREvent® ALS Single Use Patient Valve with
PEEP port, Universal Facemask – case/25 |
| |
01CV8010-cs |
CAREvent® Single Use Transport Ventilator Circuit– case/10 |
| |
01CV8015-cs |
CAREvent® Single Use Deluxe Transport Ventilator
Circuit with PEEP port– case/10 |
| |
01CV8025 |
CAREvent® Deluxe Reusable Transport Ventilator
Circuit with PEEP port |
| |
01CV8050 |
Gurney Clip (allows handheld resuscitators to be
attached to the stretcher rail) |
| |
17MP7010 |
Disposable PEEP Valve case/10 |
| |
17MP7327-cs |
Air Intake filter for ATVs case/10 |
| |
01CV7025 |
CAREvent® MRI Mounting Plate Base |
| |
01FG6500 |
Genesis® II Mask Retaining Insert |
| |
01FG6501 |
Genesis® II Mask Retaining Insert Extraction
tool |
| |
01FG6502 |
Head Harness System |
| |
01FG6520 |