| Demand
Valve Resuscitator |
|
 |
|
| |
When
Your Patients Demand 100%!!!!!
The Demand Valve Resuscitator provides a fast, simple, and
effective means to ventilate non-breathing patients and provides
100% oxygen to patients suffering from respiratory distress "On
Demand".
Designed to meet the varying requirements of the
Emergency Medical Services/Rescue Personnel, it is the only
Demand
Valve Resuscitator that comes standard with an Audible
Pressure Relief system and sensitive Manual Ventilation
Button, conveniently located on the front of the resuscitator.
The Manual Ventilation Button helps to ensure a patent
airway by enabling both hands to remain on the mask to
facilitate a superior mask to face seal (without having
to deal with cumbersome trigger levers or inconveniently
located top buttons).
The Manual Ventilation Flow rate is
fixed at 40 lpm in line with the American Heart Association "Recommendations
and Guidelines for Resuscitation".
During spontaneous
respirations, the Demand Valve resuscitator is designed
to provide 100% oxygen, to a breathing patient,
with minimal respiratory effort, with flow rates up to
160 lpm, to accommodate their own respiratory distress
situation.
Designed to operate on any 50 psi oxygen source,
the Demand Valve Resuscitator comes complete with supply
hose with
DISS fittings, and Universal Resuscitation Mask.
|
|
|
Provides fast, effective method to ventilate the
non-breathing patient. |
|
Allows both hands to remain on the mask when depressing
the Manual Ventilation Button. |
|
Durable anodized aluminum body. |
|
Provides 40 Lpm Manual Flow Rate and up to 160 Lpm Flow
Rate on Demand by the patient. |
|
Two Year warranty against manufacturers defects. |
| |
Manual Flow rate |
40 lpm |
| |
Demand Flow rate |
0-160 lpm |
| |
Demand Flow Triggering pressure |
100 lpm @ < -5 cm H2O |
| |
Input pressure |
50 PSI |
| |
Pressure Relief Valve |
60 cm H2O |
| |
Audible Over Pressure Alarm |
Yes |
| |
Operating Temperature |
-18°C to 50°C (0°F to 122°F) |
| |
Storage Temperature |
-40°C to 60°C (-40°F to 140°F) |
| |
Input Connection |
9/16" DISS |
| |
Patient Connection |
15/22 mm |
| |
Weight |
226.8 gms (8oz) |
| |
| (All specifications
are subject to a tolerance of +/- 10%.) |
 |
Part
Number and Product Description |
 |
|
 |
| |
01DV2000 |
O-Two Medical Technologies Demand Valve
Resuscitator complete with 6 Foot Supply Hose and Universal
Resuscitation Facemask |
|
| |
 |
| Demand
Valve Resuscitator Kits |
|
 |
|
| |
Ready
for any Breathing Emergency!
The Demand Valve Resuscitator
kits have been designed to meet the challenges of emergency
resuscitation. They
are ready to provide a fast, simple and effective means
to ventilate non-breathing patients and provides 100% oxygen
to patients suffering from respiratory distress "On
Demand".
Your choice of Hard Plastic or Softpack Nylon
Carrying Case, equipped with or without our Statvac II
Oxygen Powered
Aspirator.
|
|
|
Provides fast, effective method to ventilate the
non-breathing patient.
|
|
Lightweight, Moulded Orange Plastic Carrying Case
or Royal Blue Softpack Nylon Carrying Case with Shoulder Strap. |
|
Easy access to Life-saving oxygen equipment. |
|
Easy Change Oxygen Cylinder Retainer Strap. |
|
Transport Ventilation Hole. |
| |
Manual Flow rate |
40 lpm |
| |
Demand Flow rate |
0-160 lpm |
| |
Demand Flow Triggering pressure |
100 lpm @ < -5cm H2O |
| |
Input pressure |
50 PSI |
| |
Pressure Relief Valve |
60 cm H2O |
| |
Audible Over Pressure Alarm |
Yes |
| |
Operating Temperature |
-18°C to 50°C (0°F to 122°F) |
| |
Storage Temperature |
-40°C to 60°C (-40°F to 140°F) |
| |
Input Connection |
9/16" DISS |
| |
Patient Connection |
15/22 mm |
| |
Weight without Oxygen Cylinder |
907 gms (32oz) Approximate |
| |
Emergency Responder Moulded Plastic
Carrying Case: |
Exterior: L 23.3” x H 6.60” x
W 10.16”
Internal: L 21.3” x H 5.08” x W 8.64” |
| |
Color: |
International Orange |
| |
Softpack Clamshell Carrying Case: |
Exterior: L 21.8” x H 9.64” x
W 8.12”
Internal: L 20.8” x H 8.92” x W 7.12” |
| |
Color: |
Royal Blue |
|
| (All specifications
are subject to a tolerance of +/- 10%.) |
 |
Part
Number and Product Description |
 |
|
 |
| |
01DV2005 |
O-Two Medical Technologies Demand Valve
Resuscitator Kit c/w Adjustable 0 - 25 Lpm Regulator
with 2 Self-Sealing DISS Outlets in Moulded Carrying
Case with Cylinder Hand wheel (Cylinder
Not Included) |
| |
01DV2011 |
O-Two Medical Technologies Demand Valve Resuscitator
Kit c/w Adjustable 0 - 25 Lpm Regulator with 2 Self-Sealing
DISS Outlets & Statvac® II Oxygen Powered Aspirator
in Moulded Case with Cylinder Hand wheel (Cylinder
Not Included) |
| |
01DV2015 |
O-Two Medical Technologies Demand Valve Resuscitator
Kit c/w Adjustable 0-25 Lpm Regulator with 2 Self-Sealing
DISS Outlets in Softpack Clamshell Carrying Case with
Cylinder
Hand wheel (Cylinder Not Included) |
| |
01DV2025 |
O-Two Medical Technologies Demand Valve Resuscitator
Kit c/w Adjustable 0-25 Lpm Regulator with 2 Self-Sealing
DISS Outlets & Statvac® II Oxygen Powered Aspirator
in Softpack Clamshell Carrying Case with Cylinder Hand
wheel (Cylinder Not Included) |
|
| |
 |
| Equinox® II
Analgesia Administration System |
|
 |
|
| |
|
The
Equinox® II Administration System is simple, safe,
efficient way delivering pain relief during trauma, child
birth or painful procedures!
The Equinox® II Administration System is a rugged demand
inhalation unit for the administration of 50% N2O/50%
O2 analgesic
gas mixture (Entonox ALnox®) and was specifically designed for
use in emergency and obstetric analgesia.
The system consists
of a single stage pressure reducing regulator, a reinforced
supply hose, a demand valve and
a Universal patient oro-nasal mask. The Equinox® II
Demand Valve delivers high flow rates with low triggering
pressures, reducing the amount of effort required by the
patient, to maintain the demanded flow.
The light weight,
colour coded (blue) demand valve incorporates a 360° Patient
Valve Swivel Housing and is easily disassembled for cleaning.
A Bleed Pin is included with the demand valve
to effectively bleed the system of residual gas after use.
Virtually
maintenance free, the durable the Equinox® II
Administration System is a simple, safe and efficient way
of delivering pain relief during trauma, child birth or
painful procedures.
|
|
|
Provides fast, efficient method of delivering inhalation
analgesic gas. |
|
Durable anodized aluminum body. |
|
Provides up to 160 Lpm Flow Rate on Demand by the patient. |
|
Two Year warranty against manufacturers defects. |
| |
Demand Flow rate |
0-160 lpm |
| |
Demand Flow Triggering pressure |
100 lpm @ < -5 cm H2O |
| |
Input pressure |
50 PSI |
| |
Operating Temperature |
-18°C to 50°C (0°F to 122°F) |
| |
Storage Temperature |
-37°C to 60°C (-35°F to 140°F) |
| |
Input Connection |
5/8" DISS |
| |
Patient Connection |
15/22 mm |
| |
Weight |
0.24 Kg (7oz) |
| |
| (All specifications
are subject to a tolerance of +/- 10%.) |
 |
Part
Number and Product Description |
 |
|
 |
| |
01EQ7000E |
Equinox® II Administration System
complete with Regulator, Bleed Pin, 7 Foot Hose, Demand
Valve, Universal Face Mask, Cylinder Wrench |
| |
01EQ7001E |
Equinox® II Demand Valve with 7 Foot Hose |
| |
01EQ7002SQ |
SQ Equinox® II Regulator complete with Pin Indexed
Yoke and Bleed Pin |
| |
01EQ7015 |
Entonox® Scavenger Adapter |
| |
01EQ7008 |
Entonox® "E" Cylinder c/w Pin Indexed
Valve |
|
Entonox is a trademark of BOC
ALnox is a trade mark of Air Liquide |
 |
| Oxygen
Demand Valve |
|
 |
|
| |
Ready
for “On Demand” Oxygen Breathing Emergency!
The Oxygen Demand Valve provides trained individuals with
a safe and effective means of delivering 100% oxygen, by
inhalation, to patients in respiratory distress at the
flow rate demanded by the patient.
Lightweight, portable
and extremely durable the Oxygen Demand Valve is designed for
the demands of the pre-hospital
and in-hospital environment and can be used anywhere a
regulated 50 PSI oxygen supply is available.
Especially useful in areas where the provision of positive
pressure oxygen to patients in respiratory distress/arrest
is not permitted, the Oxygen Demand Valve is a simple method
of providing 100% oxygen without the wastage of gas that occurs
with free flow oxygen therapy masks.
|
|
|
Provides fast, efficient method of delivering 100%
oxygen on demand. |
|
Durable anodized aluminum body. |
|
Provides up to 160 Lpm Flow Rate on Demand by the patient. |
|
Two Year warranty against manufacturers defects. |
| |
Demand Flow rate |
0-160 lpm |
| |
Demand Flow Triggering pressure |
100 lpm @ < -5 cm H2O |
| |
Input pressure |
50 PSI |
| |
Operating Temperature |
-18°C to 50°C (0°F to 122°F) |
| |
Storage Temperature |
-40°C to 60°C (-40°F to 140°F) |
| |
Relative Humidity and Operating Use
|
15 to 95% |
| |
Input Connection |
9/16" DISS |
| |
Patient Connection |
15/22 mm |
| |
Patient Valve Dead Space
|
8 ml |
| |
Weight |
0.20 Kg (7 oz) approx. |
| |
Diameter Dimensions
|
54 x 75 mm (2.0 x 3.1 inches) approx. |
| |
| (All specifications
are subject to a tolerance of +/- 10%.) |
 |
Part
Number and Product Description |
 |
|
 |
| |
01DV3000 |
O-Two Medical Technologies Oxygen Demand
Valve complete with 6 Foot Supply Hose and Universal
Face Mask |
|
|
|